Skip to main content
Back to Earth and Space

RESOURCES & HUMAN IMPACT · WATER QUALITY

Water Quality Lab

File ▾

CHOOSE YOUR INVESTIGATION LEVEL

Is this water healthy, and how would you know?

Both levels use the same four stations: a dissolved-oxygen probe, a pond that gets a pulse of farm runoff, a stream-animal survey, and the BOD bottle and coliform plate used in water-testing labs.

About this model

① Oxygen probe. Oxygen capacity is the US EPA table for fresh water in balance with sea-level air (Volunteer Stream Monitoring: A Methods Manual, 1997, Table 5.3: 14.60 mg/L at 0 °C down to 7.54 mg/L at 30 °C), joined by straight lines between the 5 °C rows. There is no correction for salt or altitude; both lower the real capacity. The measured DO is a value you set, not a reading from a real stream. Percent saturation = measured ÷ capacity × 100, and it can pass 100% (supersaturation). Hypoxia here means DO ≤ 2 mg/L, a common convention (NOAA), not a legal or drinking-water limit.

② Runoff pond. A made-up, well-mixed teaching pond, not a forecast for any real lake. Algae grow with light and with dissolved inorganic nitrogen (one pooled pool, not nitrate alone) and phosphorus, and use them in the fixed ratio 106 C : 16 N : 1 P (the Redfield ratio, an ocean average). Algae make oxygen as they grow; dead algae and the runoff’s organic matter are decomposed, using oxygen (a carbohydrate-only proxy: nitrification and other nitrogen reactions are left out). Oxygen also mixes in from the air at the gas-exchange rate. Growth, death, decay, shading and mixing rates are supplied assumptions. In Lab 2 every pond gets the same day-1 pulse (4 mg N/L, 5 mg C/L) and the same light cut to 10% on day 12, so runoff alone is not shown to cause hypoxia. Records are every 0.5 day (a minimum between records can be missed), and the 61 records of one run are not replicates.

③ Stream survey. Five made-up samples with the same sampling effort, scored with the EPA streamside index (Table 4.2 abundance weights: each taxon present adds one weight from its tolerance group and whether it was rare 1–9, common 10–99 or dominant 100+). The nine taxon groups are a classroom simplification; real tolerance depends on family, habitat and region, so no good/fair/poor rating is given (regional cutoffs such as Maryland’s Table 4.4 need a full local taxon list). The EPA’s printed Table 4.3 example has an arithmetic slip; the Table 4.2 weights are used as published.

④ Bottle and plate tests. BOD₅ is an unseeded bottle kept dark at 20 °C for 5 days: BOD₅ = (start DO − day-5 DO) ÷ sample fraction. A run counts only if it used at least 2 mg/L and kept at least 1 mg/L (Wisconsin DNR; the older EPA volunteer manual says 2 mg/L left), and the start cannot be above the 20 °C capacity. Proper preparation and live microbes are assumed. Coliforms: CFU/100 mL = colonies × 100 ÷ (mL filtered × sample fraction). Zero colonies means below the one-colony reporting limit, not sterile water.

What no test here can do. None of these measurements shows that water is safe to drink. The model has no randomness: rerunning gives identical numbers, so reruns are not independent replicates and do not measure real-world uncertainty.

What am I looking at?

How the lab works. Pick Explore or one lab at the top. Each lab has five tabs: Pre-lab, Bench, Data & graph, Claim · Evidence · Reasoning, and Test. On the Bench, the coach lists your steps; they tick themselves as you work. Press What do I do now? when you’re stuck.

① Oxygen probe. A beaker of fresh water under air (the red pairs are oxygen molecules). Each hollow circle in the water is 0.25 mg/L of room for oxygen at this temperature; each filled blue circle is 0.25 mg/L the probe measured. Warm water has fewer circles. If the reading is above capacity, the extra oxygen leaves as bubbles at the surface. The meter shows the reading, the percent saturation and the capacity (gold dashed line on the gauge; the red band is hypoxic, ≤ 2 mg/L).

② Runoff pond. A field drains into the pond. On day 1 a brown runoff plume (yellow and green dots are phosphorus and nitrogen) washes in. Green dots are algae, the brown floor is dead organic matter (the pale specks are decomposers), and the white rings are dissolved oxygen. The sun dims and a grey screen covers the pond when the light is cut. Fish crowd the surface when oxygen is low. The DO and algae gauges are on the right.

③ Stream survey. A kick net sweeps the riffle and the catch is sorted into three rows: sensitive (blue), somewhat tolerant (gold) and tolerant (orange). Each taxon shows its count, its category (R rare, C common, D dominant) and the weight it adds to the index.

④ Bottle and plate tests (Explore). Left: a dark BOD bottle; the blue level is the oxygen left as the 5 days pass. Right: a membrane-filter plate; each blue or purple dot is one colony.

Controls. ▶ runs the station; in the pond, Step › moves exactly three days and pauses, and the speed menu slows it to 0.1× or 0.05×. Keys: Space play / pause · → step (pond) · R reset · Z / X zoom. Drag to move a zoomed-in scene.