Light & Dark Bottle Productivity Lab

AP Biology
File ▾

AP BIOLOGY UNIT 8 · AP ENVIRONMENTAL SCIENCE UNIT 1

Is the pond making oxygen, or using it?

Fill three BOD bottles with the same pond-water algae. Read one at once with a dissolved-oxygen probe. Incubate a clear bottle under a grow lamp and a foil-wrapped one beside it for 24 hours, then read them. The changes tell you how much oxygen the algae made, how much they used, and what was left over.

  1. Set the shade screens on the light bottle (or the incubator temperature).
  2. Press ▶ Incubate 24 h, then read both bottles on the DO meter.
  3. Record the run, change one thing, and repeat.

Choose where to start:

About this model

The method. Three identical BOD (biochemical oxygen demand) bottles are filled from one algae culture. The initial bottle is read straight away. The light bottle and the foil-wrapped dark bottle are sealed and incubated together, then read. NPP = (light − initial) ÷ days; R = (initial − dark) ÷ days, written as a positive amount of oxygen used; GPP = NPP + R (OpenStax Biology 2e §46.2 defines gross and net primary productivity). Rates are in mg of O₂ per litre per day.

Starting oxygen. The water starts saturated with air. Saturation comes from the Benson and Krause equation, which the U.S. Geological Survey uses for its dissolved-oxygen solubility tables (fresh water, sea-level air pressure): 11.29 mg/L at 10 °C, 9.09 at 20 °C, 7.56 at 30 °C. No salinity or altitude correction.

The algae. The rates are illustrative values for a productive pond culture, not measurements. Respiration is 2.0 mg/L per day at 20 °C and doubles for every 10 °C (Q₁₀ = 2). Photosynthesis rises with light and levels off in bright light, and is fastest near 25 °C. The model assumes respiration is the same in the light and the dark, the standard assumption of this method.

The bottles. Sealed: no oxygen enters or leaves, so the light bottle can become supersaturated (fine bubbles on the glass). DO changes at a steady rate through the incubation and never runs out within 24 h. Readings are shown to 0.01 mg/L, like a DO meter, with no random error; a real class runs replicate bottles.

Shade screens. 0, 1, 3, 5 and 8 layers of window screen pass about 100, 65, 25, 10 and 2 % of the light, the values in classic light/dark-bottle lab manuals. Real screen varies, so a class should measure its own with a light meter.

The picture. A schematic bench: proportions are close to real 300 mL BOD bottles, but sizes are not to scale across the scene.

What am I looking at?

How the lab works. Pick Explore or one lab at the top. Each lab has five tabs: Pre-lab, Bench, Data & graph, Claim · Evidence · Reasoning, and Test. On the Bench the coach lists your steps; they tick themselves as you work. Press What do I do now? when you are stuck.

The incubator. A glass water bath under a grow lamp. The temperature controller (front left) holds the water at the set temperature; the red thermometer on the right wall shows it too. In the water stand two 300 mL BOD bottles of green pond-water algae, sealed with ground-glass stoppers. The light bottle is clear; grey mesh around it is the shade screen (more layers, less light). The dark bottle is wrapped in aluminium foil, so no light reaches it.

The bench. The initial bottle was filled at the same time and read at once: the black DO probe sits in it, wired to the yellow DO meter, whose screen lists the initial, light and dark readings in mg/L. The timer shows the hours of incubation. After the run, the readings also appear over each bottle. Fine white dots on the light bottle’s glass are oxygen bubbles when it gains a lot of oxygen.

The graph. Your recorded runs: DO in each bottle after incubation, against light (or temperature in Lab 3). The ring marks the run you just finished.

Keys: Space starts or pauses the incubation · R clears the run.