Cellular Respiration Respirometer Lab

File ▾

ENZYMES & ENERGY · CELLULAR RESPIRATION

How fast are the peas breathing?

Seal peas in a vial with a CO₂ trap, sink it in a water bath, and watch dyed water creep along a pipette as the peas use up oxygen. A vial of glass beads beside them shows what the bath itself does.

  1. Press ▶ Start the timer: the bath runs for 20 minutes and every pipette is read every 5 minutes.
  2. Use the magnifier to read a pipette, and watch the graph build.
  3. Answer the coach’s questions, then write your conclusion.

1 · Choose your level:

About this model

What the respirometer measures. Cellular respiration uses O₂ and releases CO₂ (C₆H₁₂O₆ + 6 O₂ → 6 CO₂ + 6 H₂O; OpenStax Biology 2e §7.1, §7.4). KOH on the cotton absorbs the CO₂ (2 KOH + CO₂ → K₂CO₃ + H₂O), so the gas in the sealed vial shrinks only by the O₂ used, and bath water is drawn into the pipette. Change = starting reading − reading.

The numbers are a teaching model. Corrected O₂ use rises in a straight line: 0.060 mL O₂/min for germinating peas and 0.008 mL O₂/min for dry peas at 25 °C, and 0 for glass beads. These are typical classroom-sized values chosen for teaching, not measurements of one real batch of peas. Temperature follows Q₁₀ = 2 (the rate doubles for every 10 °C), so at 10 °C the rate is 2−1.5 ≈ 0.35 of the 25 °C rate; real seeds often show Q₁₀ between 2 and 3.

The bath and the bead vial. Gas expands when warmed and contracts when cooled (OpenStax Chemistry 2e §9.2). The model gives every vial in a bath the same steady physical drift, from −0.01 mL/min (warming) to +0.02 mL/min (cooling faster), because every vial holds the same volume of material and so the same volume of air. The bead vial shows that drift alone; corrected O₂ = pea change − bead change. In a real lab you also let the vials settle in the bath for about 7 minutes before the first reading.

The pipette. A 2.00 mL pipette read to the nearest 0.01 mL. Every reading starts at 1.80 mL (a drawing choice) and every reading in your table is rounded to 0.01 mL, the way you would read it.

Not included. Changes in air pressure during the run, O₂ running low inside the vial, seeds of different sizes, the time the vials need to reach the bath temperature, and harm to the peas’ enzymes at high temperatures.

Safety. KOH is corrosive. In a real lab, wear goggles and gloves, keep KOH off the peas and your skin, and never pipette by mouth.

What am I looking at?

How the lab works. Pick Explore or one lab at the top. Each lab has five tabs: Pre-lab, Bench, Data & graph, Claim · Evidence · Reasoning, and Test. On the Bench, the coach shows your next step; the list ticks itself as you work. Press What do I do now? when you’re stuck.

The bath (left picture). You are looking down into a water bath. Each respirometer is a glass vial lying on the bottom: KOH-soaked cotton at the closed end traps CO₂, a cotton plug keeps the KOH off the peas, then the peas or glass beads, a rubber stopper with a steel washer to keep it under water, and a 2.00 mL pipette. Dyed water fills the pipette from its tip. When the gas in the vial shrinks, the water’s edge (yellow ▲) moves toward the vial and the reading falls. The thermometer shows the bath temperature; the 10 °C bath has ice.

Right side. The stopwatch counts the 20-minute run; a reading of every pipette is logged at 0, 5, 10, 15 and 20 minutes. The magnifier shows one pipette’s scale up close: each small mark is 0.01 mL. Tap a vial, or a “Magnify” button, to choose which pipette it shows.

The graph. Change in gas volume (starting reading − reading) against time, one line per vial, each with its own colour, marker and dash. The orange dashed line is “now”.

Controls. ▶ Start the timer runs or pauses the bath; Next reading › jumps to the next 5-minute mark; ↺ New run sets the timer back to 0 (your recorded runs stay). Keys: Space start / pause · → next reading.